Enter your tank size, target temperature and room temperature, and pick a bioload — get the heater size and the filter flow for that tank in one step. The heater matches the temperature lift; the filter matches the bioload. Everything runs in your browser; nothing is saved.
How it works
Heater. The hobby rule of thumb is 3–5 watts per gallon, scaled by how far the tank must sit above room temperature: 3 W/gal for a lift of 5°F or less, 4 W/gal up to a 10°F lift, and 5 W/gal beyond that. The result rounds UP to a standard heater size (25 / 50 / 75 / 100 / 150 / 200 / 250 / 300 W). At 150 W and up it is better as two half-size heaters — redundancy, and a stuck heater cooks the tank more slowly.
Filter. Turnover per hour by bioload: light 4× (shrimp, betta, gentle flow), community 5×, heavy 8× (goldfish, messy eaters). Target GPH is tank gallons × turnover. Filter GPH is rated empty — media, sponges and head height cut real flow by roughly a fifth to a third, so buy a little above the number.
Presets. The target-temperature presets come from the site's own recommendations: tropical community 74°F, betta 78°F, goldfish 70°F, shrimp 72°F. Betta are solitary — a betta tank is a single-feature tank, not a community member, and the light-bioload gentle-flow note applies to them.
What it does not do. Both numbers are starting points, not guarantees. Heater sizes are rules of thumb — check with a separate thermometer and never trust a heater's own dial alone. If the room is already at or above the target, no heater is needed at all.
Worked example
A 20 gal tropical community tank, target 76°F, room 68°F.
Tank 20 gal. Target 76°F. Room 68°F. Bioload community.
Lift = target − room. Heater watts = gallons × rate (3 / 4 / 5 W/gal by lift), rounded up to a standard size. Filter GPH = gallons × turnover.
Lift = 76 − 68 = 8°F, so the rate is 4 W/gal. Heater: 20 × 4 = 80 W, rounded up to a 100 W heater. Filter: 20 × 5 = 100 GPH.
100 W heater and a filter of at least 100 GPH.
The opposite case shows the split rule. The same 20 gal tank at a 20°F lift (target 88°F, room 68°F) needs 5 W/gal: 20 × 5 = 100 W — still a single 100 W heater. But a 75 gal tank at a 15°F lift needs 75 × 5 = 375 W, which is bigger than any single standard heater, so the answer is two heaters instead of one.
How to read your results
The verdict word is the heater size — or "No heater needed" when the room is already at or above the target. Under it, the pair line shows the gallons × rate and the lift it was worked out from. The stat grid shows the three numbers that decide the purchase: heater, filter flow, and temperature lift.
A lift over 20°F shows as a Caution: a lid and keeping the tank out of drafts matter as much as watts there, and the "How to fix it" list says so. A light bioload adds a gentle-flow note — shrimp and betta want adjustable flow or a baffled output even at the right GPH. A heavy bioload adds the note that oversized filtration and water changes above the routine 25–30% are part of keeping goldfish-level waste down.
What to do next: buy the heater size shown (or two half-size heaters at 150 W and up), buy a filter rated a little above the GPH shown, and check the tank with a separate thermometer before trusting either number.
Common mistakes
- Using one heater wattage for every tank. The watts depend on the lift — a tank 5°F above the room needs far less than one 15°F above it.
- Trusting a heater's own dial. Check with a separate thermometer — heater dials are often off by several degrees.
- Buying a filter rated at exactly the GPH shown. GPH is rated empty; media, sponges and head height cut real flow by roughly a fifth to a third.
- Giving betta or shrimp a strong direct flow. Light bioload wants gentle flow — pick adjustable flow or baffle the output.
- Sizing from the daytime room temperature. If the room cools at night, size from the coldest room temperature, not the warmest.
- Running one big heater instead of two half-size ones at 150 W and up. Two heaters give redundancy, and a stuck one cooks the tank more slowly.
- Treating either number as a guarantee. Both are rules of thumb — the thermometer and the water tests are the check.
Rates and turnovers
The two tables this sizer runs on: heater rate by temperature lift, and filter turnover by bioload.
| Temperature lift | Heater rate |
|---|---|
| 5°F or less | 3 W/gal |
| Over 5°F, up to 10°F | 4 W/gal |
| Over 10°F | 5 W/gal |
| Bioload | Turnover | Example (20 gal) |
|---|---|---|
| Light — shrimp, betta | 4× per hour | 80 GPH |
| Community — tetras, rasboras | 5× per hour | 100 GPH |
| Heavy — goldfish, messy eaters | 8× per hour | 160 GPH |
Standard heater sizes the result rounds up to: 25 / 50 / 75 / 100 / 150 / 200 / 250 / 300 W. Anything above 300 W total is two heaters, not one.
FAQ
Why does the heater size change with the room temperature?
The heater only has to make up the difference between the room and the target. A tank 5°F above the room needs 3 W/gal; the same tank 15°F above it needs 5 W/gal — the lift is what decides the watts.
When does it say "No heater needed"?
When the room temperature is already at or above the target — a heater would never switch on. Re-check with the coldest room temperature, not the daytime one, before deciding.
Why two half-size heaters instead of one big one?
Redundancy and safety. If one fails, the other still heats; if one sticks on, a half-size heater cooks the tank more slowly. Put one at each end of the tank. The sizer suggests the split at 150 W and up.
What if the watts work out above 300 W?
That is bigger than any single standard heater, so the answer is two heaters — the sizer works out the half size for you.
Is the filter GPH the flow my fish actually get?
No — GPH is rated empty. Media, sponges and head height cut real flow by roughly a fifth to a third, so buy a little above the number shown.
Do betta need a different filter?
Not a different size — a gentler one. Light bioload (shrimp, betta) wants adjustable flow or a baffled output, even at the right GPH. And betta are solitary: keep one alone.
What turnover do goldfish need?
Heavy bioload, 8× per hour — plus oversized filtration and water changes above the routine 25–30%. Goldfish-level waste is what the heavy band is for.
Sources
No URLs are on file for these sources; they are listed by name.
- TheCycledTank species database — target-temperature presets (community 74°F, betta 78°F, goldfish 70°F, shrimp 72°F) and the betta-solitary rule (Our recommendation).
- Hobby rule of thumb — 3–5 watts per gallon by temperature lift, and filter turnover of 4× / 5× / 8× by bioload (Hobby practice).