Enter your equipment watts and how many hours of backup you need, and get the watt-hours a power station must hold — plus how long a battery you already own will run the load. Back up oxygen first, not the heater, and see the number before you buy. Everything runs in your browser; nothing is saved.
How it works
The priority order. Oxygen fails first, not heat — both AquaVerdia and Bluetti agree on the order. A battery air pump comes first: a heavily stocked warm tank can reach stressful oxygen levels in 4–6 hours without aeration. Filter and circulation come second, keeping water moving and the bacteria fed with oxygen. Heater or chiller comes last: temperature drifts slowly, and a 200 W heater can drain a mid-size station in an hour or two.
The formula. Watt-hours needed = total watts × hours ÷ 0.85 inverter efficiency, then × 1.2 as a 20% planning margin. The 0.85 is the inverter loss: a power station does not deliver every watt-hour its label claims — about 15% is lost converting stored DC to mains AC. Runtime from a battery you already own is the reverse: battery Wh × 0.85 ÷ load watts.
The margin is a choice, not a standard. This tool uses 20% (× 1.2). AquaVerdia suggests at least 25%; Bluetti's worked example uses 15% (× 1.15) on top of the 0.85 efficiency. No single margin is settled — treat it as planning headroom, not a guarantee, and test with your real equipment.
Heater watts are a worst case. A heater cycles on and off, so its rated watts are not its average draw. Bluetti works an example at 40% duty cycle — a 200 W heater averaging 80 W — but the real duty cycle depends on the room and the tank. This tool sizes on rated watts and says so: in a cold room the heater can stay on far longer than expected, and in a warm room far less. Measure with a plug-in power meter if you can.
Read watts off the labels. The watts for each device come from the label on the device or its power brick. A battery air pump on its own batteries needs 0 here — it does not draw from the station at all.
Worked example
A 10 W battery air pump, 12 hours of backup, and a 200 Wh power station to check.
Air pump 10 W, filter 0 W, heater 0 W. Backup needed 12 h. Battery 200 Wh.
Wh needed = total watts × hours ÷ 0.85, then × 1.2 margin. Runtime = battery Wh × 0.85 ÷ load watts.
Total load: 10 W. Before margin: 10 × 12 ÷ 0.85 = 141.18 Wh. With the 20% margin: 141.18 × 1.2 = 169.41 Wh. Runtime: 200 × 0.85 ÷ 10 = 17.0 h.
169 Wh needed (rounded), and the 200 Wh battery runs the pump about 17.0 hours — covering the 12 hours asked for, with about 5.0 hours to spare. 12 hours is moderate risk.
The heater is the trap. Add a 15 W filter and a 200 W heater to the same 12 hours and the total load becomes 225 W: 225 × 12 ÷ 0.85 = 3,176.47 Wh before the margin, 3,811.76 Wh with it. The same battery that ran the air pump for 17 hours would run this load for under an hour — which is why the heater comes last, and why insulating the tank beats feeding it watts.
How to read your results
The big number is the watt-hours needed, with the total load, the hours, and the risk band under it. The stat grid repeats the Wh needed, the total load broken down by device, and the battery runtime — or "Not entered" if you left the battery blank.
The risk band is a planning label, not a survival guarantee: under 2 hours is low risk, 2–12 hours moderate, 12–48 hours high, over 48 hours critical. It describes the outage, not your tank — a heavily stocked warm tank is in trouble sooner than a lightly stocked cool one, at the same hour count.
The rows under the stats are grouped. "Needs action" means the battery falls short or the outage is over 48 hours. "Caution" means a long outage, or the heater-duty-cycle warning. "OK" is the checklist: priority order, do not feed, manual agitation if you have no aerator, test before you need it, and flush a filter that sat still for a day or more when power returns.
If the battery falls short, the fix is in the list: drop the heater first. Every watt spent on the heater is a watt stolen from oxygen — insulate the tank with blankets or towels instead, leaving an opening for air exchange.
Common mistakes
- Backing up the heater first. Oxygen fails first — a heavily stocked warm tank can reach stressful oxygen levels in 4–6 hours. The air pump is the first watt to spend, the heater the last.
- Trusting the label watt-hours. A station's Wh is the stored energy, not the delivered energy — the 0.85 inverter efficiency is already in the maths, and the real number is lower still if the station is old or cold.
- Forgetting the inverter loss entirely. Watts × hours alone understates the need by about 18% before any margin — that is the difference between a battery that covers the night and one that dies at 3 a.m.
- Feeding during the outage. Healthy adult fish miss meals far more safely than they tolerate low oxygen or ammonia. Resume feeding gradually, about a day after power returns.
- Never testing the setup. Nameplate watts do not show startup behaviour, and a station stored empty for months may not charge when you need it. Test with your real equipment, and keep the station topped up.
- Storing the station empty. Lithium stations self-discharge; one left flat for months may not take a charge when the storm arrives.
- Restarting a still filter without flushing it. A filter that sat still for a day or more dumps stagnant water back into the tank — flush it first, and test the water the next day, because a short ammonia bump as bacteria recover is common.
Reference: outage length and risk
The outage-length guide, from FishTankSetups' timeline of how long fish live without power. These are planning labels for a typical tank, not survival guarantees — stocking, temperature and species move them.
| Outage length | Risk | What matters most |
|---|---|---|
| Under 2 hours | Low | A battery air pump alone is usually enough. |
| 2–12 hours | Moderate | Air pump and filter running; a heavily stocked warm tank can struggle after 4–6 hours without aeration. |
| 12–48 hours | High | Oxygen and filtration matter most; insulate the tank and stop feeding. |
| Over 48 hours | Critical | Plan for recharging (car, solar) or moving fish; a battery alone is unlikely to carry a tank this long. |
Bluetti's duty-cycle example is a useful sense-check on the heater: a 200 W heater at 40% duty cycle averages 80 W. This tool sizes on the full 200 W rated watts — the cautious reading — and the real draw is usually lower, except in a cold room, where it can stay on far longer than expected.
FAQ
What should I back up first in a power cut?
The battery air pump. Oxygen fails first — a heavily stocked warm tank can reach stressful oxygen levels in 4–6 hours. Filter and circulation come second; the heater comes last, because temperature drifts slowly and a heater drains a station fast.
How many watt-hours do I need?
Total watts × hours ÷ 0.85, then × 1.2 for the planning margin. A 10 W air pump for 12 hours needs 169 Wh. Add a 200 W heater to the same 12 hours and the need jumps to 3,812 Wh — which is why the heater is the trap.
How long will my power station run the tank?
Battery Wh × 0.85 ÷ load watts. A 200 Wh station on a 10 W air pump runs about 17 hours; on a 225 W load (pump, filter and heater) it runs about 0.8 hours. Enter your battery capacity and the tool does the check.
Why does the tool use rated heater watts instead of average watts?
Because the average depends on the room and the tank, and the tool cannot know it. A heater cycles on and off — Bluetti's example uses 40% duty cycle, so 200 W rated averages 80 W — but in a cold room it can stay on far longer. Sizing on rated watts is the cautious reading; measure with a plug-in power meter for the real number.
Should I feed the fish during an outage?
No. Healthy adult fish miss meals far more safely than they tolerate low oxygen or ammonia. Resume feeding gradually, about a day after power returns.
I have no aerator — what do I do?
Scoop tank water and pour it gently above the surface, repeatedly, until you have power or a pump. Breaking the surface is what exchanges gases — that is the whole job of the air pump, done by hand.
What do I do when the power comes back?
Flush a filter that sat still for a day or more before it dumps stagnant water back into the tank, and test the water the next day — a short ammonia bump as bacteria recover is common.
Sources
- AquaVerdia — Aquarium Power Backup at Home: battery air pump first, then UPS/power station, the watt-hour maths, and a margin of at least 25% (Hobby practice). aquaverdia.world
- Bluetti — Aquarium Battery Backup: load × hours, inverter losses, the 40% heater duty-cycle example, and test with real equipment (Manufacturer). bluettipower.com
- FishTankSetups — How long can fish live without power: the outage timeline, under 2 hours low risk, 2–12 hours moderate, 12–48 hours high, over 48 hours critical (Hobby practice). fishtanksetups.com
- TheCycledTank backup margin — this tool's labelled 20% planning margin (× 1.2), between AquaVerdia's 25% and Bluetti's 15% (Our method).