Enter your hydrometer reading and the water temperature, and get the true specific gravity and salinity — corrected with the EOS-80 equation of state. A warm-tank reading can be 0.001 SG off, which is a real difference at reef levels. Everything runs in your browser; nothing is saved.
How it works
A hydrometer reads true only at its calibration temperature. Warm water is less dense, so the same salt water reads low when it is warmer than the hydrometer was calibrated for — about 0.0002 SG per degree F near reef salinity — and high when it is cooler. This tool undoes that error with the EOS-80 one-atmosphere equation of state.
Observed density = reading × density of pure water at the calibration temperature. The reading is a density ratio against pure water at the calibration temperature, so multiplying it out gives the water's actual density. Pure water at 25 °C (77 °F) is 997.05 kg/m³.
Salinity = the S whose seawater density at the observed temperature equals the observed density. The tool solves the EOS-80 density equation (Millero & Poisson 1981) for S, by bisection between 0 and 60 ppt.
True SG = density of that seawater at the reference temperature ÷ density of pure water at the reference temperature. You choose the reference scale — 77 °F or 60 °F — and the correction is the true SG minus your reading.
What is ignored. The hydrometer glass itself expands with temperature, but that changes the result by less than 0.0002 SG between 60 and 90 °F, so the tool ignores it. SG here is density relative to pure water at the stated temperature, per ASTM E100.
Worked example
A swing-arm hydrometer calibrated at 77 °F reads 1.023 in 82 °F (27.8 °C) water.
Reading SG 1.023, water 82 °F (27.8 °C), hydrometer calibrated at 77 °F, result on the 77 °F scale.
Observed density = reading × pure-water density at 77 °F. Solve EOS-80 for S at 27.8 °C. True SG = seawater density at 77 °F ÷ pure-water density at 77 °F.
Observed density = 1.023 × 997.05 = 1,019.98 kg/m³. The salinity with that density at 27.8 °C is 31.7 ppt. SG of 31.7 ppt water at 77 °F = 1.0239. Correction = 1.0239 − 1.023 = +0.0009.
True SG 1.0239, 31.7 ppt, correction +0.0009 — the water is saltier than the warm reading suggested, and below the reef range.
A second case, a glass hydrometer calibrated at 60 °F reading 1.0235 in 70 °F water: the true SG is 1.0249 on the 60 °F scale (1.0244 at 77 °F), about 32.4 ppt. And at the calibration temperature itself there is no correction at all — a 77 °F hydrometer reading 1.023 in 77 °F water is truly SG 1.0230.
How to read your results
The verdict word is the headline, and the stat grid shows the three numbers behind it: the true SG on the scale you chose, the salinity in ppt, and the correction (true SG minus your reading).
In range means the true SG is 1.024–1.026, the site's reef target. Below reef range or Above reef range means the corrected number — not the raw reading — is outside it, and the rows say which way to move it, slowly.
The rows also say why the correction points the way it does: warm water reads low, so a positive correction means the true salinity is higher than the reading; cool water reads high, so a negative correction means it is lower. A correction under 0.0002 in size means the water is close to the calibration temperature and the reading was already near-true — stop chasing the thermometer.
Common mistakes
- Trusting a warm-tank reading as-is. At 82 °F a 77 °F hydrometer reads 0.0009 low — enough to mistake a below-range tank for an in-range one.
- Reading with bubbles on the hydrometer. One bubble can shift the reading by 0.001 — tap them off before reading.
- Leaving salt crust on the hydrometer. Dried salt reads high, so rinse in RO water after use.
- Measuring room air instead of tank water. The temperature that matters is the water the hydrometer is floating in, not the air around the tank.
- Using the wrong calibration temperature. Most reef hydrometers are calibrated at 77 °F, most glass ones at 60 °F — check the hydrometer itself, not the box it came in.
- Correcting a refractometer reading. A refractometer with automatic temperature compensation needs no correction at all — this tool is for hydrometers only.
Correction table — reading SG 1.023
True SG for a reading of 1.023 at each water temperature, for a hydrometer calibrated at 77 °F and one calibrated at 60 °F (both shown on the 77 °F scale). All figures recomputed with this tool's EOS-80 code.
| Water temp | 77 °F hydrometer | 60 °F hydrometer |
|---|---|---|
| 70 °F | 1.0219 | 1.0239 |
| 74 °F | 1.0225 | 1.0245 |
| 77 °F | 1.0230 | 1.0250 |
| 80 °F | 1.0235 | 1.0255 |
| 82 °F | 1.0239 | 1.0259 |
| 84 °F | 1.0242 | 1.0263 |
| 86 °F | 1.0246 | 1.0266 |
Read it as a warning about the hydrometer, not the water: the same tank reads 1.0219 on a warm day and 1.0230 at calibration temperature on a 77 °F hydrometer, while a 60 °F glass hydrometer reads the same water higher still. The water did not change — the instrument did.
FAQ
Why does my hydrometer read low in warm water?
Warm water is less dense, so the hydrometer floats lower in it — and a hydrometer measures density, not salt directly. Near reef salinity the error is about 0.0002 SG per °F: at 82 °F a 77 °F hydrometer reading 1.023 is really SG 1.0239. The salt did not change; the water's density did.
Which calibration temperature does my hydrometer use?
Most reef swing-arm hydrometers are calibrated at 77 °F (25 °C) and most glass hydrometers at 60 °F (15.6 °C), with some at 68 °F. The calibration temperature is printed on the hydrometer itself — check it there, not on the box, and enter it in the form.
What is the difference between the 77 °F and 60 °F scales?
They are two ways of stating the same density: SG is measured against pure water at a stated temperature, and pure water is denser at 60 °F than at 77 °F. The same water is SG 1.025 at 77 °F and SG 1.0255 at 60 °F. Always say which scale a number is on before comparing two readings.
When can I ignore the correction?
When it is under 0.0002 — that is smaller than the reading error from one bubble (0.001) and smaller than the glass-expansion effect the tool ignores. That happens when the water is within about a degree of the calibration temperature. At 82 °F against a 77 °F hydrometer the correction is +0.0009, which is worth applying.
Do I need this tool if I use a refractometer?
No — a refractometer with automatic temperature compensation needs no correction at all. This tool is for hydrometers only: swing-arm or glass, calibrated at 60, 68 or 77 °F.
How do I get a reliable hydrometer reading?
Tap off any bubbles, read at eye level, note the water temperature at the same moment, and rinse the hydrometer in RO water after use so dried salt crust does not read high next time. Then correct the reading for temperature — or switch to a refractometer calibrated with 35 ppt fluid.
Sources
- Peer-reviewed — Millero & Poisson (1981). International one-atmosphere equation of state of seawater. Deep-Sea Research 28A: 625–629. Used for the EOS-80 density equation behind the correction.
- Standard — UNESCO (1981). Technical Papers in Marine Science 38. Used for the pure-water density against temperature (997.05 kg/m³ at 25 °C) and the equation of state.
- Standard — ASTM E100. Standard Specification for ASTM Hydrometers. Used for the definition of SG as density relative to pure water at a stated temperature.
These are a journal paper and two standards, listed by name; no web link was on file for them.