Salinity Converter

The number your hydrometer, refractometer or probe gave you

Conversions are approximate at 25°C (77°F) — the temperature reef hydrometers are calibrated for. The site's reef target is SG 1.024–1.026.

What is this salinity?

Enter a salinity value in any unit — the same salinity in all four units appears here, with whether it sits inside the reef target.

Why use this calculator?

  • Convert between specific gravity, ppt, PSU and percent in one step, so a hydrometer reading, a label and a reef target all speak the same language.
  • Use real EOS-80 seawater physics at 25°C instead of the old linear shortcut — SG 1.025 is 33.2 ppt, not 35 ppt.
  • See at a glance whether the reading sits inside the site's reef target of SG 1.024–1.026, and which way to move it if it does not.
  • Remember that evaporation raises salinity, so top off with fresh RO/DI water — topping off with salt water raises it further.

Saltwater means RO/DI water for top-offs and mixing — tap water brings in things a reef does not want. Freshwater numbers live in the Water Parameter Checker. · Back to Saltwater & Reef

Enter a salinity value in any unit and get it in all four — specific gravity, ppt, PSU and percent. Everything runs in your browser; nothing is saved.

It converts between all four units at once, so a hydrometer reading can be checked against the reef target without working through the conversion by hand.

How it works

Specific gravity (SG) is the density of your salt water divided by the density of pure water at the same temperature. Because water gets less dense as it warms, an SG number is only meaningful with its reference temperature attached — this tool works at 25 °C (77 °F), the temperature reef hydrometers are calibrated for.

SG = density of seawater at salinity S and 25 °C ÷ density of pure water at 25 °C. The densities come from the EOS-80 one-atmosphere equation of state (Millero & Poisson 1981, adopted by UNESCO 1981). Pure water at 25 °C is 997.05 kg/m³.

SG to ppt. The tool solves the density equation backwards: it finds the salinity S whose seawater density at 25 °C, divided by 997.05, equals your SG reading. That is the ppt figure.

PSU and percent. Practical salinity (PSU) tracks ppt numerically for our purposes, so the PSU number equals the ppt number. Percent is ppt ÷ 10 — 33.2 ppt is 3.32% salt.

Conductivity. A probe measures conductivity in mS/cm, converted to salinity by the PSS-78 practical salinity scale. This tool does not calculate conductivity, but the reference table below lists it so a probe reading can be matched to a salinity.

The reef target. The site's own water target for reef tanks is SG 1.024–1.026 (about 32–35 ppt). Fish-only saltwater often runs lower, 1.020–1.024, and brackish water sits around SG 1.005–1.015 (about 7–20 ppt).

Worked example

A refractometer reads SG 1.025 at 77 °F, with the hydrometer and the reading both at 25 °C.

Inputs

SG 1.025, reference temperature 77 °F (25 °C).

Formula

SG = density of seawater ÷ density of pure water at 25 °C (EOS-80). Pure water at 25 °C = 997.05 kg/m³. PSU = ppt; percent = ppt ÷ 10.

Calculation

Target density = 1.025 × 997.05 = 1,021.98 kg/m³. Solving EOS-80 for the salinity with that density at 25 °C gives S = 33.19 ppt. Percent = 33.19 ÷ 10 = 3.32%. PSS-78 gives 50.6 mS/cm, and the same water reads SG 1.0255 on the 60 °F scale.

Result

SG 1.025 = 33.2 ppt = 33.2 PSU = 3.32% salt — in range for a reef tank (SG 1.024–1.026).

A second check, going the other way: natural seawater at 35 ppt is SG 1.0264 on the 77 °F scale and 1.0269 on the 60 °F scale, at 53.1 mS/cm. And a probe reading 53.0 mS/cm is 34.95 ppt, or SG 1.0263.

How to read your results

The verdict word is the headline, and the stat grid shows the three numbers behind it: the specific gravity at 25 °C, the salinity in ppt (the same number in PSU), and the percent salt.

In range means SG 1.024–1.026, the site's reef target — about 32–35 ppt. Below reef range means the water is fine for fish-only saltwater at the low end, but low for corals — raise it slowly, never all at once. Above reef range means bring it down gradually with RO/DI top-offs — fast swings stress everything in the tank.

Read the rows under the verdict for the next step. "Caution" means fix it soon; "OK" means that check passed. The tool judges only the salinity number — it cannot tell you whether the salt mix, the temperature or the measuring instrument is the problem, so check those too.

Common mistakes

  • Using the old linear shortcut (SG − 1) × 1,400. It reads high by about 1.8 ppt — SG 1.025 is 33.2 ppt by EOS-80, not 35 ppt.
  • Comparing SG numbers from different reference temperatures. The same water is SG 1.025 at 77 °F and SG 1.0255 at 60 °F — always note which scale a reading is on.
  • Calibrating a refractometer with RO water. Calibrate with 35 ppt calibration fluid, not RO water — RO calibration leaves the reading off at reef levels.
  • Topping off evaporation with salt water. Evaporation leaves the salt behind, so only the water needs replacing — top off with fresh RO/DI water, or salinity climbs every day.
  • Reading a hydrometer in warm tank water and taking the number at face value. Warm water reads low — about 0.0002 SG per °F near reef salinity — so correct the reading for temperature first.
  • Treating ppt and PSU as different units to convert between. For aquarium purposes they are the same number; converting one to the other changes nothing.

Salinity at a glance (25 °C / 77 °F)

Specific gravity, ppt, conductivity and the same water's SG on the 60 °F scale. The ppt and 60 °F figures are recomputed with this tool's EOS-80 code; the conductivity column follows the PSS-78 scale.

SG (77 °F)pptmS/cmSG (60 °F)
1.01013.322.11.0102
1.01519.932.01.0153
1.02026.641.51.0204
1.02229.245.21.0224
1.02330.547.01.0234
1.02431.948.81.0244
1.02533.250.61.0255
1.02634.552.41.0265
1.02735.854.21.0275

Natural seawater is 35 ppt — SG 1.0264 at 77 °F, 1.0269 at 60 °F, 53.1 mS/cm. The reef target (SG 1.024–1.026) sits just below natural seawater, at about 32–35 ppt.

FAQ

What salinity should a reef tank run at?

SG 1.024–1.026 at 25 °C, about 32–35 ppt — the site's own water target for reef tanks. Natural seawater is 35 ppt (SG 1.0264), so the reef target sits just below it. Fish-only saltwater often runs lower, 1.020–1.024.

Why does this tool say SG 1.025 is 33.2 ppt when other converters say 35 ppt?

The 35 ppt figure comes from the old linear shortcut (SG − 1) × 1,400, which reads high by about 1.8 ppt. Real seawater density follows the EOS-80 equation of state, and by that physics SG 1.025 at 25 °C is 33.19 ppt. This tool uses EOS-80, so it reads lower — and matches a calibrated refractometer — where the shortcut reads high.

Is PSU the same as ppt?

Numerically, yes, for aquarium purposes — 33.2 ppt is 33.2 PSU. PSU is the practical salinity scale (PSS-78), defined through conductivity rather than a weighed salt mass, but the numbers agree at the precision a hobby test can measure.

Does temperature change the conversion?

Yes — SG is a density ratio, and density changes with temperature. The same water reads SG 1.025 at 77 °F and SG 1.0255 at 60 °F. This tool converts at 25 °C (77 °F); if your reading was taken at another temperature, correct it first with the Hydrometer Temperature Correction Calculator.

Why is my hydrometer reading different from my refractometer?

Usually temperature, bubbles, or calibration. A hydrometer reads true only at its calibration temperature and reads low in warm water; one bubble on it can shift the reading by 0.001; and a refractometer calibrated with RO water instead of 35 ppt fluid reads off at reef levels. Correct the hydrometer reading for temperature, tap off bubbles, and calibrate the refractometer with 35 ppt fluid before comparing.

Does evaporation change salinity?

Yes — evaporation removes pure water and leaves the salt behind, so salinity climbs. Top off daily with fresh RO/DI water, never with salt water. Topping off with salt water adds more salt to a tank that already has too much.

Sources

  1. Peer-reviewed — Millero & Poisson (1981). International one-atmosphere equation of state of seawater. Deep-Sea Research 28A: 625–629. Used for the EOS-80 density equation behind every conversion on this page.
  2. Standard — UNESCO (1981). Technical Papers in Marine Science 36 and 37 (EOS-80 and PSS-78). Used for the equation of state and the practical salinity scale, including the conductivity figures in the table.
  3. Peer-reviewed — Lewis, E. L. (1980). The practical salinity scale 1978 and its antecedents. IEEE Journal of Oceanic Engineering OE-5: 3–8. Used for the PSS-78 conductivity-to-salinity relationship.

These are journal papers and technical reports, listed by name; no web link was on file for them.

Related tools