Enter your display volume, turnover, lift, pipe run and elbows — get the flow your sump return pump must deliver AT your system's total dynamic head, so you can match it to a manufacturer's pump curve instead of a zero-head rating. Everything runs in your browser; nothing is saved.
How it works
Target flow. Target flow (GPH) = display volume (gal) × turnover (× per hour). The turnover ranges come from the AquariumCalculator.net guide table: freshwater community 4–6×, planted low-tech 3–4×, CO2 high-tech 5–8×, goldfish / cichlid 8–10×, FOWLR 6–10×, reef return 6–10×, reef circulation 10–40×. The range is a guide, not a rule for every stocking level.
Total dynamic head. Total dynamic head (ft) = vertical lift + pipe friction + elbow loss. The head-loss approximations come from the same source family: about 1 ft of head per 10 ft of 1 in pipe, and 0.5–1 ft per 90° elbow — pick 0.5 ft for smooth / long-sweep elbows, 1 ft for tight 90° elbows. Those two figures are approximations, not measured values for your system: real friction loss rises with flow rate (roughly with the square of flow), so a fixed per-10-ft figure overstates head at low flow and understates it at high flow, and it assumes 1 in pipe — other diameters differ.
Hydraulic power (estimate only). Power (W) = (flow GPH × head ft) ÷ (318.1 × efficiency), with efficiency defaulting to 0.5. The 318.1 divisor comes from first principles for these units (power = density × gravity × flow × head: 1 GPH = 1.0515e-6 m³/s, 1 ft = 0.3048 m). Note that kwcalc.com publishes 367 — but that constant is for flow in cubic metres per hour and head in metres giving kilowatts. Applied to GPH and feet it reads about 13% low, so it is not used here. Treat the wattage as a ballpark, never as a spec; real power draw comes from the manufacturer's data.
Return vs circulation. Reef circulation 10–40× is powerheads, not the return pump: the return pump moves water through the sump (6–10× for reef), and powerheads provide the extra in-tank circulation. Picking the circulation row shows the total-circulation target for comparison only — do not size a return pump to it.
What it does not do. This tool covers sump return pumps only — filter turnover is the Heater & Filter Sizer's job, not this one. Head loss is estimated, not measured; a pump's real delivered flow at a given head comes only from its own curve; and pipe runs with reducers, check valves, manifolds, reactors or UV units add head this tool does not count. Always check the manufacturer's pump curve and measure the real flow (for example with a bucket and a stopwatch at the display outlet) before trusting any number here.
Worked example
A 75 gal reef tank, sump return at 8× turnover, 4 ft of lift, 20 ft of pipe, 2 elbows at 0.5 ft each, efficiency 0.5.
Volume 75 gal. Turnover 8× (reef return). Lift 4 ft. Pipe 20 ft. Elbows 2 × 0.5 ft. Efficiency 0.5.
Flow = volume × turnover. Head = lift + pipe ÷ 10 + elbows × loss each. Power = (flow × head) ÷ (318.1 × efficiency).
Flow = 75 × 8 = 600 GPH. Pipe loss = 20 ÷ 10 = 2 ft. Elbow loss = 2 × 0.5 = 1 ft. Head = 4 + 2 + 1 = 7 ft. Power = (600 × 7) ÷ (318.1 × 0.5) = 26.4 W.
Your pump must deliver 600 GPH at 7 ft of head — about 26.4 W of hydraulic power, rough estimate only. Buy the pump whose curve gives 600 GPH at 7 ft, not the one rated 600 GPH at zero head.
The same system with tight elbows (1 ft each) has 8 ft of head instead of 7 — and the pump must still deliver 600 GPH there. That is why the elbow choice matters: it moves the head, and the head moves which pump qualifies.
How to read your results
The verdict word is the flow at the head: "600 GPH at 7 ft of head". Under it, the pair line shows the volume × turnover it was worked out from. The stat grid shows the three numbers that decide the purchase: target flow, total head, and the rough hydraulic power.
The turnover row says whether your turnover sits inside the usual guide range for the setup you picked — outside it is a Caution, not an error, and the "How to fix it" list says to pick a turnover inside the range or check that your stocking justifies going outside it. Picking reef circulation adds its own Caution: that 10–40× total is powerheads, and sizing a return pump to it buys far too much pump.
What to do next: take the flow-at-head number to the manufacturer's pump curve, find your head on it, and buy the pump that delivers the flow there. Then measure the real flow at the display outlet with a bucket and a stopwatch.
Common mistakes
- Buying on the zero-head rating. A pump rated 600 GPH at zero head delivers far less at 7 ft of head — the curve at your head is the number that matters.
- Sizing the return pump to the circulation total. Reef circulation 10–40× is powerheads; the return pump is 6–10×.
- Guessing the lift. Measure from the sump water level up to the display outlet — a foot of guessed lift is a foot of wrong head.
- Ignoring reducers, check valves, manifolds, reactors and UV units. They all add head this tool does not count, so the real head is higher and the real flow lower.
- Using the pipe figure for a different diameter. The 1 ft per 10 ft approximation assumes 1 in pipe — other diameters differ.
- Treating the turnover range as a rule. It is a guide — stocking, planting and flow needs can justify going outside it, but check first.
- Trusting the power estimate as a spec. It is a ballpark from an assumed efficiency; real power draw comes from the manufacturer's data.
Usual turnover by setup
The turnover guide this calculator checks against (AquariumCalculator.net). Reef circulation is powerheads, not the return pump.
| Setup type | Usual turnover |
|---|---|
| Freshwater community | 4–6× per hour |
| Planted, low-tech | 3–4× per hour |
| CO2 high-tech planted | 5–8× per hour |
| Goldfish / cichlid | 8–10× per hour |
| FOWLR (fish-only saltwater) | 6–10× per hour |
| Reef — sump return | 6–10× per hour |
| Reef — total circulation (powerheads) | 10–40× per hour |
Turnover ranges: turnover guide, AquariumCalculator.net. Reef circulation 10–40× is powerheads, not the return pump.
FAQ
What is total dynamic head?
Everything the pump has to push against: the vertical lift from the sump water level to the display outlet, plus friction in the pipe, plus the loss at each elbow. The pump must deliver your target flow at that total — not at zero head.
Why is my pump's rated GPH not the flow I get?
The rating is usually the zero-head flow. At 7 ft of head the same pump delivers far less — which is why you match the flow-at-head number to the manufacturer's pump curve.
What is the 318.1 in the power estimate?
The divisor that makes the hydraulic-power formula work in GPH and feet, from first principles. kwcalc.com publishes 367, but that is for cubic metres per hour and metres giving kilowatts — applied to these units it reads about 13% low, so this tool uses 318.1. Either way the watts are a ballpark, not a spec.
Can I use this for my canister filter?
No — this tool covers sump return pumps only. Filter turnover is the Heater & Filter Sizer's job.
Do I count the pipe inside the display?
Count the whole return pipe run from the pump to the display outlet, in feet. Measure it — a guessed pipe length is a guessed head.
What if my turnover is outside the usual range?
The calculation still runs, and the result is flagged as a Caution. Check whether that turnover fits your stocking — a guide range is not a rule for every tank.
Sources
- AquariumCalculator.net — turnover guide table and head-loss approximations (about 1 ft of head per 10 ft of 1 in pipe; 0.5–1 ft per 90° elbow) — aquariumcalculator.net (Hobby practice).
- kwcalc.com — hydraulic power formula, constant 367 for m³/h and metres giving kilowatts (the 318.1 divisor used here is the same formula converted to GPH and feet, from first principles) — kwcalc.com (Calculator reference).