TDS / Conductivity Converter

The factor decides the answer — and it is an estimate

A TDS meter is really an EC meter with a fixed factor built in. The factor depends on which salts are dissolved and on your meter's own setting, so the ppm figure is an estimate unless the factor matches your meter. True TDS is measured by evaporating a weighed sample in a lab.

Pick the direction you are converting in
Your TDS reading in ppm, or your EC reading
1 mS/cm = 1,000 µS/cm — ignored for TDS → EC
Match your meter's factor — check its manual or settings
Between 0.01 and 1.00 — 0.64 is the common agricultural (640 scale) figure

TDS (ppm) = EC (µS/cm) × factor; EC (µS/cm) = TDS (ppm) ÷ factor; 1 mS/cm = 1,000 µS/cm (factors from GenetixBay and ppmtoppb.com). Worked examples: 300 ppm ÷ 0.50 = 600 µS/cm = 0.60 mS/cm, and back, 600 µS/cm × 0.50 = 300 ppm. At factor 0.70: 420 ppm ÷ 0.70 = 600 µS/cm, and 600 µS/cm × 0.70 = 420 ppm. The same water at 1.0 mS/cm reads 500 ppm on a 500-scale meter and 700 ppm on a 700-scale meter. EC readings should be temperature-corrected to 25 °C — conductivity rises about 2% per °C.

Your converted reading

Enter a value and pick a factor — the reading in TDS and in both EC units appears here.

Why use this calculator?

  • Convert both ways — TDS to EC and EC to TDS — with the factor your meter actually uses.
  • See the result in both µS/cm and mS/cm, so you never mix up the two EC units.
  • Enter your own custom factor when your meter uses the 0.64 agricultural scale or anything else.
  • Know why two meters disagree by 40% on the same water — and why working in EC avoids the problem entirely.

Check what the reading means for your fish with the Water Parameter Checker, or convert hardness units with the Hardness Converter. · Back to Water Chemistry

Convert between TDS in ppm and electrical conductivity in µS/cm and mS/cm, in both directions — with the NaCl 0.50 factor, the 442 0.70 factor, or your own custom factor. Worked examples: 300 ppm ÷ 0.50 = 600 µS/cm = 0.60 mS/cm, and back, 600 µS/cm × 0.50 = 300 ppm. The page states plainly that the factor depends on your water and your meter, so the ppm figure is an estimate unless the factor matches. Everything runs in your browser; nothing is saved.

How it works

Two formulas, one factor. TDS (ppm) = EC (µS/cm) × factor, and EC (µS/cm) = TDS (ppm) ÷ factor. The EC units are exact: 1 mS/cm = 1,000 µS/cm, so the tool shows both and you never have to move a decimal point by hand.

The factors. 0.50 is the NaCl / 500 scale, common in North America: on it, 1.0 mS/cm reads 500 ppm. 0.70 is the 442 / 700 scale, based on a 442 reference mix of sodium sulfate, sodium bicarbonate and sodium chloride: on it, 1.0 mS/cm reads 700 ppm. A third figure, 0.64 — the 640 scale for agricultural and mixed municipal water — appears in the same sources but is not a preset here; enter it as a custom factor. The custom field accepts any factor from 0.01 to 1.00, so a KCl-scale meter (about 0.55) is covered the same way.

Why it is an estimate. A TDS meter does not weigh anything: it measures conductivity, then multiplies by a fixed factor to estimate dissolved solids. The true factor depends on which salts are dissolved, and it rises with conductivity — about 0.65 at 1,000 µS/cm to about 0.82 at 10,000 µS/cm (NDSU). True TDS is measured gravimetrically, by evaporating a weighed sample and weighing the residue. The EC route is an estimate, usually within 10–20% for typical waters. Match the factor to your meter — if your meter applies its own fixed factor, use the same value here so this calculator agrees with what your meter displays.

Temperature. EC readings should be temperature-corrected to 25 °C. Conductivity rises about 2% per °C, so a reading taken in cold water is not comparable with one taken in warm water unless the meter compensates. Use a meter with automatic temperature compensation, or test at about 25 °C.

Worked example

A TDS pen reads 300 ppm on the NaCl / 500 scale. What is that as conductivity?

Inputs

300 ppm TDS, factor 0.50 (NaCl / 500 scale), converting TDS to EC.

Formula

EC (µS/cm) = TDS (ppm) ÷ factor. mS/cm = µS/cm ÷ 1,000.

Calculation

300 ÷ 0.50 = 600 µS/cm. Then 600 ÷ 1,000 = 0.60 mS/cm.

Result

600 µS/cm = 0.60 mS/cm. Back the other way: 600 × 0.50 = 300 ppm.

The same water on the other scale: 420 ppm ÷ 0.70 = 600 µS/cm = 0.60 mS/cm, and 600 µS/cm × 0.70 = 420 ppm. With a custom 0.64 factor: 500 µS/cm × 0.64 = 320 ppm, and 500 ÷ 1,000 = 0.500 mS/cm.

Calibration check from the meter guides: a 1.413 mS/cm calibration solution reads 1,413 µS/cm, which is 1,413 × 0.50 = 706.5 ppm on the 500 scale and 1,413 × 0.70 = 989.1 ppm on the 700 scale — about 707 and 989 ppm.

How to read your results

The headline is the converted value — conductivity if you started from TDS, TDS if you started from conductivity — with the factor and scale named beside it. The stat grid shows all three numbers together: TDS in ppm, conductivity in µS/cm, and conductivity in mS/cm, so you can quote whichever unit the chart you are reading uses.

The one number to trust for comparisons is the EC. Two meters can disagree by 40% in ppm on the same water — 1.0 mS/cm reads 500 ppm on a 500-scale meter and 700 ppm on a 700-scale meter — while their µS/cm readings agree exactly. So when a guide, a forum post or a water report gives a TDS number, ask which scale it used; when you compare two of your own readings, compare them in µS/cm.

What to do next depends on the reading. For shrimp, the typical-readings table below is the reference — but stability matters more than the exact number, so track the trend week to week rather than chasing a single reading. If the number looks wrong, check the factor first: a reading that is 40% off your expectation is usually the wrong scale, not the wrong water.

Common mistakes

  • Comparing ppm numbers from two meters on different scales. The same water reads 500 ppm on a 500-scale meter and 700 ppm on a 700-scale meter — neither meter is broken.
  • Forgetting the factor entirely and treating a TDS pen's ppm as a weighed measurement. It is an EC reading multiplied by a fixed factor — an estimate, usually within 10–20% for typical waters.
  • Mixing up µS/cm and mS/cm. 600 µS/cm is 0.60 mS/cm, not 600 mS/cm — a factor-of-1,000 error that shows up as an impossible reading.
  • Comparing EC readings taken at different temperatures without compensation. Conductivity rises about 2% per °C; use a meter with automatic temperature compensation or test at about 25 °C.
  • Using the simple factor for saltwater. It only holds in fresh water — seawater is about 53,000 µS/cm (53 mS/cm), so use the Salinity Converter for saltwater and brackish readings.
  • Treating TDS as hardness. TDS counts all dissolved solids; hardness counts calcium + magnesium. Use the Hardness Converter for GH and KH.
  • Assuming 0.64 is a preset. It is not — enter it as a custom factor. The same goes for the KCl scale at about 0.55.

Conversion table

Conductivity to TDS at the three common factors. The 0.64 column is the custom-factor case.

EC (µS/cm)EC (mS/cm)TDS at 0.50 (ppm)TDS at 0.64 (ppm)TDS at 0.70 (ppm)
500.05253235
1000.10506470
2000.20100128140
3000.30150192210
5000.50250320350
1,0001.00500640700

Typical readings

Typical fresh-water readings, with the TDS column at the 0.64 factor. Shrimp targets are ranges to hold steady, not exact numbers — stability matters more than the precise figure.

WaterEC (µS/cm)TDS (ppm, at 0.64)
RO / DI water0–150–10
Caridina tank200–300130–190
Neocaridina tank250–400160–260
Typical tap water200–800130–510
Rift Lake tank400–700260–450
Seawater~53,000Use the Salinity Converter

FAQ

Why do two TDS meters disagree on the same water?

Because they use different factors. The same water at 400 µS/cm reads 200 ppm on a 0.5 pen and 280 ppm on a 0.7 pen — neither is wrong, they use different conventions. Compare readings in µS/cm, which every meter agrees on, or state the scale with the ppm number.

Which factor should I use?

The one your meter uses — check its manual or settings for NaCl, KCl or 442. In North America most pens are 0.50; the 442 / 700 scale is common for natural-water meters. If the manual does not say, 0.64 is a fair middle figure for tap water, entered as a custom factor.

What is the 0.64 factor?

The 640 scale, for agricultural and mixed municipal water — the middle of the usual 0.50–0.70 range. It is not a preset on this page because the tool only ships the two named scales plus custom; enter 0.64 in the custom-factor field and the tool uses it exactly like a preset.

Does temperature change the reading?

Yes — conductivity rises about 2% per °C. Readings should be temperature-corrected to 25 °C, which is what a meter with automatic temperature compensation does. A reading taken in cold water without compensation is not comparable with one taken in warm water.

Can I use this for saltwater?

No. The simple factor only holds in fresh water. Seawater is about 53,000 µS/cm (53 mS/cm) — for saltwater and brackish readings use the Salinity Converter instead.

Is TDS the same as hardness?

No. TDS counts all dissolved solids; hardness counts calcium + magnesium only. A soft-water tank can still read a high TDS if something else is dissolved in it. Use the Hardness Converter for GH and KH.

Sources

  1. Hobby practice — GenetixBay, EC / ppm scales. genetixbay.com Used for the 0.50 and 0.70 factors, the 1 mS/cm = 1,000 µS/cm relation, the 1.413 mS/cm calibration check (about 707 ppm on the 500 scale, about 990 ppm on the 700 scale), and the NDSU factor range.
  2. Hobby practice — ppmtoppb, EC-to-TDS calculator. ppmtoppb.com Used for TDS = EC × factor, the 600 µS/cm × 0.5 = 300 ppm example, the 0.64 figure for mixed municipal supplies, and the estimate being usually within 10–20% for typical waters.
  3. Standard — APHA / AWWA / WEF, Standard Methods, Method 2510 (Conductivity) and Method 2540 (Solids). Used for the standard framing: conductivity in µS/cm at 25 °C, and TDS estimated as conductivity × an empirical factor, typically 0.55–0.7 for natural waters.
  4. Government — USGS, "Conductivity (Electrical Conductance) and Water". Used for how dissolved ions carry current and why conductivity tracks dissolved solids.
  5. Government / University — NDSU Extension WQ1923 (rev. 2025), via GenetixBay. Used for the true factor not being constant: about 0.65 at 1,000 µS/cm rising to about 0.82 at 10,000 µS/cm.
  6. Hobby practice — ppmcalculators, ppm-to-EC. ppmcalculators.com Used as a cross-check for the factors, including 500 ppm ÷ 0.50 = 1,000 µS/cm.

Related tools