Work out what your calcium reactor actually supplies in dKH and ppm per day — or work backwards from your corals’ daily demand to the effluent rate in mL/min and drops per minute. Everything runs in your browser; nothing is saved.
How it works
A calcium reactor dissolves calcium carbonate media with CO₂-acidified water. The water leaving the reactor — the effluent — carries alkalinity and calcium at far higher concentrations than the tank, and the drip of effluent into the tank is what doses them. The supply is a mass balance: what flows out of the reactor each day, minus what the tank already holds, spread over the system volume.
Effluent per day (L/day) = effluent rate (mL/min) × 1.44. One mL per minute is 1,440 mL a day, which is 1.44 litres a day.
Alkalinity supplied (dKH/day) = effluent per day × (effluent dKH − tank dKH) ÷ system litres. Only the gap between effluent and tank alkalinity counts — effluent at the same alkalinity as the tank adds nothing, however fast it drips.
Calcium supplied (ppm/day) = effluent per day × (effluent Ca − tank Ca) ÷ system litres, when you have measured effluent calcium. Without it, the tool estimates calcium from the alkalinity: Ca (ppm/day) = dKH/day × 7.15, because 1 dKH is 0.3566 meq/L (APHA Standard Methods 2320) and 1 meq of alkalinity pairs with 20.04 mg of calcium, so 0.3566 × 20.04 = 7.15 mg/L of calcium per dKH.
Rate for a demand (mL/min) = demand (dKH/day) × system litres ÷ ((effluent dKH − tank dKH) × 1.44). Drops per minute are the rate × 20, on the standard-drip approximation that about 20 drops make 1 mL — an approximation, so measure the real rate by collecting effluent for a minute.
Worked example
A 150-gallon SPS reef (567.8 L), effluent 60 mL/min at 25 dKH, tank at 8 dKH.
System 150 gal (567.8 L); effluent 60 mL/min at 25 dKH; tank 8 dKH.
Effluent/day = mL/min × 1.44. dKH/day = L/day × (effluent − tank) ÷ litres. Ca/day = dKH/day × 7.15.
60 × 1.44 = 86.4 L/day of effluent. 86.4 × (25 − 8) ÷ 567.8 = 86.4 × 17 ÷ 567.8 = 2.59 dKH/day. Calcium: 2.59 × 7.15 = 18.5 ppm/day. Drips: 60 × 20 = 1,200 drops/min.
2.59 dKH/day and about 18.5 ppm calcium/day — the estimated calcium, since no effluent calcium was measured.
The same reef, worked backwards: to supply exactly 1.5 dKH/day, the rate is 1.5 × 567.8 ÷ (17 × 1.44) = 34.8 mL/min, or 696 drops/min, which is 50.1 litres of effluent a day and about 10.7 ppm of calcium a day.
And with a measured effluent calcium: effluent 600 ppm against a tank at 430 ppm, at the same 60 mL/min, gives 86.4 × 170 ÷ 567.8 = 25.9 ppm/day — higher than the 7.15 estimate. That gap is a sign to check the test kit or the media, not a better result.
How to read your results
The verdict word is the headline: "Supplying" in the supply mode, "Rate needed" in the rate mode, or "No supply at this setting" when the effluent alkalinity is at or below the tank's. The stat grid shows the three numbers behind it — alkalinity supplied per day, calcium supplied per day, and the effluent rate (or, in rate mode, the rate, the effluent volume per day, and the calcium supplied).
"No supply" means the gap is zero or negative: effluent at the same alkalinity as the tank adds nothing at any flow rate. Fix the effluent alkalinity first — usually by lowering effluent pH with more CO₂ — then re-check. Do not fix it by opening the flow valve; flow without a gap still supplies nothing.
Read the rows under the verdict for the next step. "Needs action" means do it now. "Caution" means fix it soon — the usual one here is the CO₂ the effluent carries into the tank. "OK" means that check passed. A calcium figure marked "estimated" is the 7.15 ppm-per-dKH figure; enter effluent calcium to replace it with a measured one.
Common mistakes
- Changing CO₂ and flow at the same time. A reactor tuned by two changes at once cannot be diagnosed — change one, measure tank alkalinity daily for a week, then change the other.
- Trusting a drip rate set once and never re-measured. Drip rates drift; re-measure a day after any change, by collecting effluent in a cylinder for one minute or counting drops for 15 seconds × 4.
- Using the tank's label volume instead of the net water volume. Display plus sump, minus rock and substrate — a 150-gallon tank rarely holds 150 gallons of water, and the supply per day is divided by the real volume.
- Reading the estimated calcium as a measured one. The 7.15 figure assumes the media dissolves in the balanced ratio; a measured effluent calcium that disagrees is information, not an error to ignore.
- Forgetting the effluent carries CO₂. It can lower tank pH — aeration or kalkwasser top-off offsets it.
- Running the effluent pH too low. Below about 6.3 the reactor wastes CO₂ and dissolves media unevenly; too high and it barely works. Typical effluent is in the 20s–30s dKH at effluent pH about 6.5–6.8.
Effluent rate for a daily demand (150 gal, 25 dKH effluent, 8 dKH tank)
The rate this reef needs for each daily alkalinity demand, from the same mass balance as the worked example. All figures recomputed with the tool's own formula.
| Demand (dKH/day) | Effluent rate (mL/min) | Drops/min |
|---|---|---|
| 0.5 | 11.6 | 232 |
| 1.0 | 23.2 | 464 |
| 1.5 | 34.8 | 696 |
| 2.0 | 46.4 | 928 |
| 3.0 | 69.6 | 1,392 |
The rate scales with the demand and with the system volume, and falls as the effluent–tank gap grows: richer effluent needs a slower drip for the same daily supply.
FAQ
Why does the reactor add alkalinity and calcium together?
The media is calcium carbonate, and dissolving it releases calcium and alkalinity in the ratio corals use them — roughly 7.15 ppm of calcium for each dKH of alkalinity. That is why the tool can estimate the calcium supply from the alkalinity supply, and why a reactor keeps the two in step instead of dosing them separately.
My measured calcium supply is different from the estimate — which is right?
The measured one, once you trust the tests. The estimate assumes balanced dissolution; a big mismatch usually means a test error or unusual media, so re-test effluent calcium and tank calcium with the same kit before changing the reactor.
What effluent alkalinity should I aim for?
Typically in the 20s–30s dKH, at an effluent pH of about 6.5–6.8. Below about pH 6.3 the reactor wastes CO₂ and dissolves media unevenly; much above 6.8 and it barely works. Measure the effluent alkalinity at the reactor outlet — do not guess it from the CO₂ setting.
Can I just turn the flow up to dose more?
Flow raises the supply, but it also pushes more CO₂-carrying effluent into the tank, which can lower tank pH. Change one thing at a time and measure tank alkalinity daily for a week before the next change. If the effluent alkalinity is at or below the tank's, more flow adds nothing at all.
How do I measure the effluent rate?
Collect the effluent in a measuring cylinder for one minute, or count the drops for 15 seconds and multiply by 4. The tool converts mL/min to drops/min at about 20 drops per mL, which is a standard-drip approximation — the collected volume is the real rate.
Does a reactor replace water changes or two-part dosing?
No. A reactor maintains steady levels against daily use; it does not correct a low reading quickly, and it does not replace the trace elements and magnesium a water change refreshes. For a correction dose, use the Reef Dosing Calculator, and work out the daily use first with the Reef Daily Consumption Planner.
Sources
No source URLs are on file for these references, so they are listed by name without links.
- Standard — APHA / AWWA / WEF, Standard Methods, Method 2320. Alkalinity: 1 dKH = 0.3566 meq/L, and 1 meq of alkalinity pairs with 20.04 mg of calcium — the two figures the 7.15 ppm-per-dKH calcium estimate is calculated from.
- Hobby practice — Holmes-Farley, R., Reefkeeping Magazine / Advanced Aquarist. Calcium reactors, effluent chemistry, CO₂ and effluent pH, and balanced calcium/alkalinity supply. Used for the mass-balance method and for the effluent pH and alkalinity guidance on this page.
- Method — mass balance. Supply = effluent volume per day × (effluent concentration − tank concentration) ÷ system volume; 1 mL/min = 1.44 L/day. This is arithmetic on the two concentrations, not a separate source, and it is the whole basis of the tool.