Reef Daily Consumption Planner

Same salinity at both tests

Test at the same time of day, with the same test kit, and at the same salinity — about a 1 ppt rise in salinity reads as about +13 ppm calcium (a reported figure), so a test pair taken at different salinities makes calcium use look smaller than it is. A water change between the two tests adds parameters back and lands in the result as false consumption.

Test at the same time of day — 24–48 h apart, or 4 days with no dosing in between, as Red Sea’s manual prescribes

Net water volume, after rock and sand

For the kalk check only — measure it from the water-level drop over a week

Alkalinity (dKH)

How much your dosing between the two tests raised Alk — from the product label, or 0 if you did not dose

…in 100 L, from the product label — for the daily mL dose. Never guessed here.

Calcium (ppm) optional

How much your dosing between the two tests raised calcium — from the product label, or 0 if you did not dose

…in 100 L, from the product label — for the daily mL dose

Magnesium (ppm) optional

How much your dosing between the two tests raised magnesium — from the product label, or 0 if you did not dose

…in 100 L, from the product label — for the daily mL dose

Daily use = (first test − second test + rise from dosing between the tests) ÷ days between tests, for alkalinity (dKH/day), calcium (ppm/day) and magnesium (ppm/day). Daily dose (mL) = daily use ÷ (rise per mL per 100 L from your product label) × (system litres ÷ 100). Kalk ceiling ≈ evaporation (L/day) × 40 meq/L ÷ system (L), converted at 1 meq/L = 2.8 dKH — saturated kalkwasser carries about 40 meq/L of alkalinity (BRS guidance), so the ceiling is approximate. Consumption is always measured from your own two tests — this tool never estimates it. Method: Seafan consumption tool, citing the Red Sea Foundation manual v21a and Complete Reef Care 2024.

How much do your corals use each day?

Enter the days between the tests, your system volume, and at least one full pair of test readings — the daily use for each parameter, the daily product dose, and the kalk check appear here.

Why use this calculator?

  • Turn two test readings into a standing daily dose — so parameters stay steady instead of swinging between corrections.
  • See alkalinity, calcium and magnesium use side by side, from the same test pair, instead of working each one out separately.
  • Know whether kalkwasser alone can keep up with your tank, before you set the ATO to dose it.
  • Works with any two-part brand, because the product strength comes from the label you hold — never a guessed number.
  • Count dosing done between the tests properly, so a dosed test pair still gives a true daily use.

If a reading is already low, work out the correction dose with the Reef Dosing Calculator — this planner matches daily use, it does not raise a low reading. Check whether kalk alone can meet a measured demand in detail with the Kalkwasser Calculator, and measure evaporation with the Evaporation & Top-Off Planner. · Back to Saltwater & Reef

Turn two test readings into a standing daily dose for your reef tank: enter alkalinity, calcium and magnesium tests taken 24–48 hours apart (or 4 days with no dosing in between, as Red Sea's manual prescribes), any dosing done between the tests, and your system volume. The planner works out how much your corals use each day, the daily millilitres of your own two-part product to match it, and whether kalkwasser alone can keep up. Consumption is always measured from your own tests — never estimated. Everything runs in your browser; nothing is saved.

How it works

Consumption is a rate, and a rate needs two measurements. Test once, dose nothing, test again days later: the fall between the two readings, plus anything your dosing added back in between, divided by the days, is the daily use. That is the whole method — no estimate of what corals "should" use, only what your tank's tests say they did use.

Daily use = (first test − second test + rise from dosing between the tests) ÷ days between tests. Alkalinity in dKH/day, calcium and magnesium in ppm/day. The rise from dosing comes from the product label — how much the dose you gave between the tests raised the reading — or 0 if you did not dose.

Daily dose (mL) = daily use ÷ (rise per mL per 100 L from your product label) × (system litres ÷ 100). The rise per mL per 100 L is your product's strength, read off its own label: 1 mL of it raises the parameter by that much in 100 litres. Brands differ, so the strength is entered, never guessed — without it the tool shows the daily use but no product dose.

Kalk ceiling ≈ evaporation (L/day) × 40 meq/L ÷ system (L), converted at 1 meq/L = 2.8 dKH. Saturated kalkwasser carries about 40 meq/L of alkalinity (BRS guidance), so the most alkalinity kalk can add in a day is the evaporation volume times that concentration, spread over the system. The ceiling is approximate: the Kalkwasser Calculator on this site uses the 0.00114 dKH-per-mL-per-100-L constant instead, which implies about 40.7 meq/L, so the two routes differ by roughly 2% — 2.24 dKH/day here against 2.28 there for 2 litres of evaporation a day in 100 litres. That is rounding, not a real disagreement; re-test before acting on a borderline result.

The test protocol. Red Sea's Foundation manual prescribes a 4-day test with no dosing in between. This tool also accepts shorter gaps (24–48 hours) and dosing between the tests, provided the rise from that dosing is entered. Either way: same time of day, same test kit, same salinity, no water change in between.

Worked example

Alkalinity 8.0 → 7.2 dKH over 2 days in 100 litres, no dosing in between; calcium 420 → 400 ppm over the same 2 days with 10 ppm dosed; magnesium 1,350 → 1,320 ppm over 4 days; evaporation 2 litres a day.

Inputs

100 L; Alk 8.0 → 7.2 over 2 days; Ca 420 → 400 over 2 days, 10 ppm dosed; Mg 1,350 → 1,320 over 4 days; evaporation 2 L/day.

Formula

Daily use = (first − second + dosed) ÷ days. Dose (mL) = daily use ÷ potency × (litres ÷ 100). Kalk ceiling = evap × 40 ÷ litres × 2.8.

Calculation

Alk: (8.0 − 7.2) ÷ 2 = 0.4 dKH/day. Ca: (420 − 400 + 10) ÷ 2 = 15 ppm/day. Mg: (1,350 − 1,320) ÷ 4 = 7.5 ppm/day. Kalk ceiling: 2 × 40 ÷ 100 × 2.8 = 2.24 dKH/day.

Result

0.4 dKH/day, 15 ppm Ca/day, 7.5 ppm Mg/day. Kalk covers the 0.4 dKH/day easily — 2.24 is the ceiling, so the use is 17.9% of it.

With product strengths from the label, the use becomes a dose. Alkalinity at 0.1 dKH per mL per 100 L: 0.4 ÷ 0.1 × (100 ÷ 100) = 4 mL/day, 28 mL/week. Calcium at 2 ppm per mL per 100 L: 15 ÷ 2 × (100 ÷ 100) = 7.5 mL/day. In a 200-litre system the same use needs twice the product — 8 mL/day of the alkalinity product.

And the shortfall case: the same 0.4 dKH/day of alkalinity use, but 0.5 litres of evaporation a day in 200 litres. The ceiling is 0.5 × 40 ÷ 200 × 2.8 = 0.28 dKH/day, so kalk alone cannot keep up — the shortfall is 0.12 dKH/day to cover with two-part dosing.

How to read your results

The verdict word is the headline: "Daily use worked out" when the test pair is clean, "Unusually high use — re-test" when alkalinity use is above 1.4 dKH/day, or "A reading rose — re-test" when a parameter went up between the tests. The stat grid shows the three daily-use numbers — a dash means that parameter was not entered.

Each row under the verdict is one parameter's arithmetic, shown in full: the two readings, any dosed rise, the days, the daily use and the weekly use, and the daily product dose where a label strength was entered. "No daily product dose shown" means the potency field was left blank — the tool will not guess your product's strength.

The kalk row compares your evaporation ceiling with your alkalinity use: "Kalk alone can keep up" with the percentage of the ceiling used, or "Kalk alone CANNOT keep up" with the shortfall in dKH/day. The ceiling is approximate (about 40 meq/L), so a borderline result — use within a few percent of the ceiling either way — should be confirmed with a repeat test pair, not acted on as a certainty.

A row marked "Needs action" means dose nothing on that result and re-test. A row marked "Caution" means check the warning before dosing — the usual ones are high alkalinity use and a salinity change between the tests. "OK" means that check passed.

Common mistakes

  • Testing at different times of day or with different kits. Alkalinity swings through the day and kits disagree with each other — a pair taken under different conditions measures the conditions, not the consumption.
  • Doing a water change between the tests. It adds parameters back and lands in the result as false consumption — or hides real consumption entirely.
  • Topping off with salt water, or letting salinity drift. About a 1 ppt rise in salinity reads as about +13 ppm calcium (a reported figure, not independently verified here), so a test pair taken at different salinities makes calcium use look smaller than it is.
  • Forgetting dosing done between the tests, or guessing its rise. The rise must come from the product label; an under-reported rise understates the use, and the dose that follows is wrong in the same direction.
  • Using the tank's label volume instead of the net water volume. Display plus sump, minus rock and sand — the dose is divided by the real volume.
  • Dosing on a negative result. A parameter that rose between the tests gives a negative daily use, which means something added it — a water change, the salt mix, or under-reported dosing. Dose nothing on it; re-test.
  • Treating the kalk ceiling as exact. It rests on "about 40 meq/L" for saturated kalk, and the Kalkwasser Calculator's own route gives a figure about 2% higher. Close to the ceiling either way, re-test.
  • Using this planner to fix a low reading. It matches daily use; it does not raise a low reading. A correction dose belongs on the Reef Dosing Calculator.

Daily use from the worked example

All three parameters from the worked example, each with its own test gap. All figures recomputed with the tool's own formula. Note the magnesium pair spans 4 days (the Red Sea test length) while the alkalinity and calcium pairs span 2 days.

ParamFirstSecondDosedDaysDaily useWeekly use
Alk (dKH)8.07.2020.4 dKH/day2.8 dKH/week
Ca (ppm)42040010215 ppm/day105 ppm/week
Mg (ppm)1,3501,320047.5 ppm/day52.5 ppm/week

Weekly use is the daily use × 7 — a planning figure for how much a week of consumption adds up to, not a dose to give at once. Never raise alkalinity by more than 1.4 dKH in a single day.

FAQ

Why do I need two tests instead of one?

Consumption is a rate — how fast a level falls — and one reading cannot show a rate. Two readings days apart give the fall, and dividing by the days gives the daily use. A single low reading only says the level is low; it says nothing about how fast it got there or how much to dose each day.

Why 4 days with no dosing?

That is Red Sea's Foundation manual prescription: long enough for the fall to be bigger than test-kit error, with no dosing to account for. Shorter gaps (24–48 hours) work too, and this tool accepts them, but the shorter the gap the more test error matters — and any dosing in between must have its rise entered from the label.

A reading went up between the tests — what now?

Dose nothing on that result. A rise means something added the parameter: a water change, the salt mix, or dosing whose rise was under-reported. Re-test at the same salinity with no dosing in between, and check the other parameters' rows — a genuine rise in one and a fall in another points at the salt mix or a water change, not at the corals.

Why does the tool need my product's strength from the label?

Two-part brands differ in concentration, so 1 mL of one brand is not 1 mL of another. The strength — how much 1 mL raises the parameter in 100 litres — is printed on the label, and the dose is computed from it. The tool never guesses a strength, because a guessed strength makes the dose wrong by the same factor.

Can I use this to fix a low reading?

No. This planner matches daily use so levels stay steady; it does not raise a low reading. Work out the correction dose on the Reef Dosing Calculator, then use this planner's daily dose to hold the corrected level.

Why does salinity matter between the two tests?

About a 1 ppt rise in salinity reads as about +13 ppm calcium, so a test pair taken at different salinities makes calcium use look smaller than it is. That figure is a reported one from the research behind this tool, not independently verified here — but the precaution costs nothing: test at the same salinity, top off with fresh RO/DI only, and do no water change between the tests.

Kalk covers my alkalinity use — do I still need two-part?

For alkalinity and calcium, no — kalk adds both in the ratio corals use them. For magnesium, yes: kalk carries no magnesium, so the magnesium row's daily use still needs its own dosing. And if evaporation falls (a lid, a fan switched off, winter), the ceiling falls with it — re-check the kalk row when the seasons change.

Sources

No source URLs are on file for these references, so they are listed by name without links. Two figures carry explicit uncertainties — see the entries.

  1. Hobby practice — Seafan consumption tool (reef.cameronshields.co.uk). The method this tool follows: daily use from two tests days apart, the daily product dose from the label strength, and the kalk ceiling from evaporation. Seafan cites the Red Sea Foundation manual v21a and Complete Reef Care 2024. Those underlying references were cited in the research report behind this tool and were not live-verified against the original pages in this build.
  2. Manufacturer — Red Sea Foundation manual v21a. The 4-day test with no dosing in between, and the daily maximum of 1.4 dKH for raising alkalinity. Cited via Seafan (see above); the manual itself was not live-verified in this build.
  3. Hobby practice — Bulk Reef Supply kalk guidance. Saturated kalkwasser carries about 40 meq/L of alkalinity — the figure the kalk ceiling is computed from. The "about" matters: the Kalkwasser Calculator's route implies about 40.7 meq/L, roughly 2% higher, and the page states the difference rather than hiding it.
  4. Reported figure, not independently verified — salinity effect on calcium readings. About a 1 ppt rise in salinity reads as about +13 ppm calcium. This figure comes from the research report behind this tool and was not independently verified here; the page says so, and the precaution (same salinity at both tests) stands either way.

Related tools